Testing procedure according to IEC 801 Section 4

  • Test for interference immunity against bursts (coupling to lines)
    The test values are divided into 5 steps: Stage Power lines Data and control lines
    1 0.5 kV 0.25 kV
    2 1.0 kV 0.5 kV
    3 2.0 kV 1.0 kV
    4 4.0 kV 2.0 kV
    X special special

Test procedure according to IEC 801, Section 2

  • Electrostatic discharge on the surface and surroundings of the test object.
    The test values are divided into 4 classes:
    Class Test voltage
    1 2 kV
    2 4 kV
    3 8 kV
    4 15 kV
  • Radio interference according to VDE 0871